Product Specification :AXPERT-Opti-Torque

                                   Click here for
|Product Description|Specification|Brochure|Manual| 

Power

380~460Vac, 3-Phase, 3-Wire, 50/ 60 Hz

Tolerance 

Voltage tolerance: +10%, -20%, Frequency tolerance: ±5%

AMT-OT-   

037

045

055

075

090

110

132

160

200

250

315

400

450

500

585

630

710

Max Continuous Rated Current (A) (Inline)

72

87

110

147

175

215

245

320

360

470

590

720

800

880

950

1065

1200

Max Applicable motor (kW) (Inline)

37

45

55

75

90

110

132

160

200

250

315

400

450

500

585

630

710

Max Cont. Rated Motor Current (A) (Inside Delta)

122

148

187

250

298

366

417

544

612

799

1003

1224

1360

1496

1615

1811

2040

Control

Control system

Digital 32-bit Digital Signal Processor

Standard digital inputs

Start, Stop, Programmable Inputs 1 ~ 6

+24V supply

Max. Total current drain from terminal = 100mA

Serial port

Supports RS485

Operation Specifications

Current feed back &

Thermal OLR

Motor current: Adjustable up to 0.3 x Unit Current Rating

I-Low Level: 0 ~ 100% of full load motor current

I-Limit Level: 100 ~ 500% of full load motor current

I-Trip Level: 100 ~ 550% of full load motor current

I-Low Time: 0 ~ 20 minutes

I-Limit Time: 10 ~ 60 seconds

Digital Inputs

2-Fixed inputs for Run and Stop, 6-Programmable Sequence Inputs, Sink / Source changeable

Programmable between 12 different options: Not Used, Terminal select, Ext Fault, Fault reset, Emergency stop, Phase Angle Firing Selection, Ref Increase/ Ref Decrease for static potentiometer, Ref select 0 & 1, PID Bypass and PID Disable

Digital Outputs

4 Programmable digital sequence outputs Open collector type

Programmable between 13 different options: Not Used, Ready, Run, Terminal, Fault Alarm, Power Limit Alarm, I-Limit Alarm, Low Current Alarm, High Current Alarm, Temp Alarm, Vout Limit Alarm, PID Up Limit, PID Lo Limit.

Potential Free Contacts

2-Programmable relays:

1-NO, 1-NC for 2A @ 240Vac

Programmable between 13 different options same as digital outputs

Fault Relay: 1-NO, 1-NC for 2A @ 240VAC

Programmable Analog Outputs

2-Programmable analog voltage outputs VO1 & VO2: 0~10Vdc

2-Programmable analog current outputs IO1 & IO2: 4~20mA

Programmable between 6 different options: Output Voltage, Output Current, Active Power, Reactive Power, Heat sink temperature, PID Output

Start Mode

V-Ramp Start

Dual Ramp Selection

V-Ramp Up Time1: 1 ~ 240 sec

Pedestal-1: 25 ~ 90%

Kick Time: 0 ~ 2.0 sec

Kick Voltage: 0 ~ 90%

Target: 25 ~ 100%

I-Ramp Start

I-Ramp Up Time: 1 ~ 60 s