2171 West Park Court, Suite # G, Stone Mountain, GA
|
|
|
|
|
|
Motion Control
|
Product
SPECIFICATION :"AXPERT-EAZY"
Series AC Drive
|
|
Power
|
380~460Vac,
3-Phase, 3-Wire, 50/ 60 Hz
|
Tolerance
|
Voltage
tolerance: ±10%, Frequency tolerance: ±5%
|
AMT
|
045
|
055
|
075
|
090
|
110
|
132
|
160
|
200
|
250
|
315
|
400
|
450
|
500
|
630
|
Max
Continuous Rated Current (A) Note1
|
87
|
110
|
147
|
175
|
215
|
245
|
320
|
360
|
470
|
530
|
675
|
720
|
775
|
970
|
Max
Applicable motor (kW) Note2
|
45
|
55
|
75
|
90
|
110
|
132
|
160
|
200
|
250
|
315
|
400
|
450
|
500
|
630
|
Control
Functions
|
Control
Method
|
Digital
Space Vector PWM Control
|
Frequency
Range
|
0.1~600Hz
For V/F Control
|
Frequency
Accuracy
|
Digital
references: ±0.01% (0 ~ 50șC)
|
Analog
References: ±0.1% (0 ~ 50șC)
|
Output
Frequency Resolution
|
0.0001Hz
(20-bit)
|
Frequency
Setting Resolution
|
0.01Hz
Digital, 0.012Hz/50Hz Analog (12-bit)
|
V/
Hz Characteristics
|
2-Preprogrammed
patterns, 1-Custom 3-point setting pattern
|
Torque
Boost
|
Manual
/ Automatic Selective: 0~20%
|
Acceleration/
Deceleration Time
|
0.1~
6,00,000 Seconds
|
Linear
or S-Curve selective
|
Skip
Frequency
|
Three
frequencies can be set, band can be set up
to 10.0Hz
|
Slip
Compensation
|
Slip
compensation frequency up to 5.0Hz
|
Carrier
Frequency Note3
|
Default:
5kHz, 2~10kHz
|
Default:
4kHz, 2~6kHz
|
Operation
Specifications
|
Speed
Search Function
|
When
enabled, rotating motor can be started at
any moment
|
Bump
less transfer for redundancy application
(Optional)
|
Power
Loss Carry Through
|
Up
to 5 seconds for smooth operation of
system during power loss
|
DC
Braking
|
DC
Braking start frequency 0.1~50 Hz, Time:
0~25 seconds, Brake current: 15 to150%
|
Frequency
Setting Input
|
Digital
Input: Digital Operation Panel (Local) or
Serial RS485
|
Potentiometer:
2 k Ohm
|
FSV:
0~5Vdc or 0~10Vdc (or Inverse)
|
FSI:
0~20mA or 4~20mA (or Inverse)
|
Static
Pot: Freq Increase/ Frequency Decrease
using digital input
|
Preset
Speeds: Using Preset input-0, 1 & 2
|
Torque
Setting Input
|
Digital
Input: Digital Operation Panel (Local) or
Serial RS485
|
Potentiometer:
2 k Ohm
|
FSV:
0~5Vdc or 0~10Vdc (or Inverse)
|
FSI:
0~20mA or 4~20mA (or Inverse)
|
Programmable
Analog Inputs
|
VIN:
0~10Vdc (or Inverse)
|
IIN:
0~20mA or 4~20mA (or Inverse)
|
Input
Commands
|
Run,
Stop, Reverse, Jog, Preset input-0, 1
& 2, Frequency Increase/ Frequency
Decrease for static potentiometer, Run
command with maintained / momentary
facility, Ramp select, Aux drive select,
Emergency stop, Fault reset, Ext Fault,
Terminal select, Ref select 0 & 1.
|
|
|
Digital
Inputs
|
2-Fixed
inputs for Run and Stop, 6-Programmable
Sequence Inputs, Sink / Source changeable
|
Programmable
between 16 different options: Not Used, Jog
Select, Ramp Select, Preset i/p-0, Preset i/p-1,
Preset i/p-2, Freq Increase, Freq Decrease,
Aux Drive, Emergency Stop, Fault Reset, Ext
Fault, Reverse, Terminal, Ref Select 0, Ref
Select 1
|
Digital
outputs
|
4-Programmable
Sequence Outputs, open collector type
|
Programmable
between 17 different options: Not Used, Run,
Local, Reverse Run, I-Detection, Freq
Attain, Speed Detect1, Speed Detect2,
Acceleration, Deceleration, Aux Drive, Timer
Output, Zero
Speed, Fault Alarm, PID Up Limit, PID Lo
Limit, Temp Alarm
|
Potential
Free Contacts
|
2-Programmable
relays:
|
1-NO,
1-NC for 2A @ 240Vac
|
Programmable
between 17 different options same as digital
outputs
|
1-Fault
relay: 1-NO, 1-NC for 2A @ 240Vac
|
Programmable
Analog Outputs
|
2-Programmable
analog voltage outputs VO1 & VO2:
0~10Vdc
|
2-Programmable
analog current outputs IO1 & IO2: 4~20mA
|
Programmable
between 6 different options: Output
Frequency, Output Current, Output Power,
Output Voltage, DC Bus Volt, PID Output
|
Network
connectivity
|
RS-485
for PC Interface with Modbus-RTU protocol as
standard
|
Auto
Restart
|
Adjustable
up to 5 times for ten faults
|
PID
Controller
|
Inbuilt
PID can be used as stand alone
|
Display
|
Display
and Keypad module
|
20-Character,
4-Line LCD panel, 8-Key keypad, 3-Status
indicating LED for Run, Stop and Fault
|
Protective
Specifications
|
Protective
Function
|
Current
Limit, Over current fault, Timed over
current fault, Load side short circuit
fault, Under current fault, Over voltage
fault, Under voltage fault, Temperature
fault, Input / Output phase loss fault,
Ground fault, External fault, Charging
fault, Current sensor fail fault, EEPROM
Fault, 4~20mA reference missing fault, Auto
tuning fault, Emergency stop, Communication
loss, Input phase reverse fault.
|
Smooth
Operation
|
Speed
Search, Auto Restart and Power Loss Carry
Through functions, Heat sink over
temperature alarm
|
Fault
history
|
Last
ten faults with status and eight operational
parameters like output frequency, output
current, dc bus voltage and heat sink
temperature.
| | | | | |