2171 West Park Court, Suite # G, Stone Mountain, GA
|
|
|
|
|
|
Motion Control
|
AXPERT
Opti-torque
Electronic Soft Starter is
a modern Digital Signal
Processor based highly
functional Soft Starter
that is easy to use. Six
thyristors are used in
back to back connection.
The control board uses 32-bit
High-Performance Digital
Signal Processor and
generates the necessary
gate pulses for Soft
Starter operation. It
accepts various inputs
from different circuits
and Digital Operation
Panel (LCD
Keypad Module) to
generate the necessary
control and gate signals.
The
unit is equipped with
Digital Operation Panel
(LCD Keypad Module) for
the user interface. It has
32-bit ARM controller.
All parameters of Soft
Starter can be accessed
from Digital Operation
Panel. The Digital
Operation Panel consists
of LCD display Board and
8-key keypad.
Models:
50 to 1000HP
Features
:
 |
Three
Start Modes:
Voltage ramp
start, Current
ramp start and
Torque ramp start |
 |
Four
Stop Modes:
Voltage ramp stop,
Torque ramp stop,
Brake stop and
coast-to-stop |
 |
Three
Control Modes:
Keypad, Terminal
and Serial |
 |
Inbuilt
Power Meter (kW,
kVAR, Power
Factor) |
 |
Inbuilt
Energy Meter (kWh,
MWh)
|
 |
Available
with Inline,
Inside Delta and
Bypass
Configuration
|
 |
Inbuilt
PID Control |
 |
Kick
Start / Jog
Function |
 |
Dual
Ramp Function in
voltage ramp mode |
 |
Auto
Restart
|
 |
Complete
Motor Protection
|
 |
Fault
History: Last 10
Faults are stored
in non-volatile
memory with
|
 |
information
of 4 important
operational
parameters
|
Display
And Interface
 |
80-Character,
4-Line LCD with
Back Light and
8-key Keypad for
easy parameter
monitoring and
navigation
|
 |
Self-explanatory
full parameter
name displayed in
English on Digital
Operation Panel
for easy
programming
|
 |
Easy
parameter
navigation through
well defined MODE,
NORM, GROUP, UP
and DOWN Keys
|
 |
3-Status
indicating LED for
RUN, STOP and
FAULT condition
|
 |
8
Selectable
parameter
monitoring on
single screen
|
 |
RS-485
Modbus
communication as
standard
|
 |
PC
Interface Software
|
 |
Motor
Current monitoring
of all the three
phases
|
 |
8
Programmable
Digital Input with
selectable SINK
& SOURCE logic
|
 |
4
Programmable
Digital output
(Open Collector
Type)
|
 |
3
Programmable
Digital output
(Potential Free
Contact)
|
 |
4
Programmable
Analog Input (two
0-10V and two
4-20mA)
|
 |
4
Programmable
Analog Output (two
0-10V and two
4-20mA)
|
Protection
:
 |
Over
Current Fault
|
 |
Over
Frequency Fault |
 |
Over
Load Fault |
 |
Under
Frequency Fault |
 |
True
Ground Fault
|
 |
Emergency
Stop
|
 |
Under
Current Fault |
 |
Main
Contactor Fault
|
 |
Phase
Loss Fault |
 |
Bypass
Contactor Fault
|
 |
Over
Voltage Fault |
 |
Reverse
Contactor Fault
|
 |
Temperature
Fault |
 |
Communication
Loss
|
 |
Phase
direction Fault
|
 |
External
Fault
|
 |
I-Unbalance
Fault |
 |
EEPROM
Fault
|
 |
Firing
Fault |
|
|
Applications
:
|
|
|
|
|
|
|
|
|
|